24
Data Register
The Data register contains the transmission data/slave address or the receipt data byte.
In transmit mode, the byte is sent most-significant bits first.
In receive mode, the first bit received is placed in the register’s most-significant bits.
After each byte transmits, the Data register contains the byte present on the bus; therefore, if
arbitration is lost, the Data register has the correct receive byte.
Table 3-10. Data Register
BIT 7 6 5 4 3 2 1 0
OFFSET
D002
FIELD
Transmission Data/Slave Address or Receipt Data Byte
RESET
0 0 0 0 0 0 0 0
RW
RW RW RW RW RW RW RW RW
Table 3-11. Data Register Definitions
Bits Field Name Description
7:0 SLA6 – SLA0
Transmission Data/Slave Address or Receipt Data Byte