4: Configuration Using XML
PremierWave EN Command Reference 24
ip ip time to live Default: 64 hops
multicast time to live Default: 1 hops
line
(Attribute of
“instance” is a
number.)
name
interface rs232, rs485 half-
duplex, rs485 full-
duplex, usb-cdc-acm
Default:
termination enable, disable Default: disable
state enable, disable Default: depends on
instance
protocol none, tunnel Default:
baud rate Default: 9600 bits per
second
parity even, none, odd Default: none
data bits 7, 8 Default: 8
stop bits 1, 2 Default: 1
flow control none, hardware,
software
Default: none
xon char Accepts a control
character, for example,
<control>A
represents control-A
Default: <control>Q
xoff char Accepts a control
character, for example,
&#60;control&#62;A
represents control-A
Default: <control>S
gap timer &#60;None&#62;, ... Default: <None>
threshold Default: 56 bytes
Group Name
(continued)
Group Item Value Name Value Options Additional
Information